WinBuild 5000 Version 2.4 (6/26/2006)
Bug Fixes
RS485 Transmission Error
Scripting Editor
Downloading to a Compact Flash through Winbuild 5000
Displaying of non-numeric characters
Image File creation
VNC Viewer
NVRAM corruption at download
WinBuild 5000 Version 2.3 (12/20/2006)
New Features
Added new alarm wizard option, in Winbuild5000.exe.
Winbuild 5000 now uses Unicode Fonts
WinBuild 5000 Version 2.2 (9/14/2006)
New Features
WinBuild 5000 Version 2.10 (5/1/2005)
New Features
WinBuild 5000 Version 1.17 (4/20/2004)
Bug fixes
WinBuild
5000 Version 1.16 (
What’s
New
Added
LOCKMUTEX, UNLOCKMUTEX, SYSTEM basic commands
Added
MTS FLX driver
Bug
fixes
Fixed
COM INIT pseudocode for user-defined delimiters above 127
Fixed
saving of Fast Screen Switch checkbox
Fixed
bit read/writes for Mitsubishi FX driver
Fixed
IO reads for Compumotor Ethernet
Fixed
rare non-volatile access problem
WinBuild
5000 Version 1.15 (
What’s
New
Mitsubishi
FX driver.
Yaskawa
SMC TCP/IP motion controller driver.
Downloading
to an attached CompactFlash drive.
Downloading
to Image, which can then be downloaded to an attached CompactFlash driver
with a freely-distributed download-only tool.
Recipe
system speed enhancements
Bug
fixes
Pulling
the power after download and program restart no longer results in the old
program not getting saved to disk.
WinBuild
5000 Version 1.14 (1/28/2003)
What’s
New
Added
automatic background updating for HMI objects and background execution for
WhileOpen code making screens extremely responsive, regardless of the
devices you’re reading or code you’re running.
Added
Fast Screen Switching option to Hardware properties.
Fast Screen Switching doesn’t wait for valid data from a device
before switching to the screen.
Converted
Modbus communication object into an ActiveX DLL.
Added
Array Read, Array Write, and methods to convert arrays to and from text
files.
Documented
ActiveX object and provided the Visual Basic source code for the Tag Watcher
and 6500 IO configuration programs, in the Common Files/ESA Technology
directory.
Bug
fixes
Fixed the recipe system’s copy screen to properly error out when there are no open records or when you attempt to copy to an already existing record. It also properly cleans up on exit so the recipe select screens work. The recipe screens must be regenerated for the updated basic code to be added.
WinBuild
5000 Version 1.13 (12/17/2003)
Whats New
Code
added to popup numeric and alpha data entries to close popup after 30
seconds. To use on existing
programs, delete the _PopupNum and _PopupAlpha screens, save and close the
program, and reopen it. This
will recreate the popup screens with the new code.
Moved
some files to Common Files/ESA Technology folder
Bug fixes
Modbus RTU now has a proper inter-packet delay
HMI switch screen now looks better
No more use of scientific notation for Galil numeric tag writes
Internal Galil problems all resolved
Timer one shot enable/max/disable/reset/enable problem fixed
Averaging code added to PC104-15 to reduce noise
Automation
Direct driver fixed -- some addresses wouldn't work
New data
types added to Automation Direct driver
POS
function fixed
LEN
function now returns signed value, making it work in FOR loops
TIME,
TIME$, and System Driver TIME and TIME$ tags fixed
Nonvolatile
driver strings no longer padded to maximum size with NULLs
Driver
Put Gets check to make sure the driver is online was causing problems
with Galil Terminal mode
WinBuild
no longer creates error message for Internal Galil driver with no DMC
program selected
WinBuild
5000 Version 1.12 (
Whats
New
HMI
now more responsive as display items now update in background
Modbus
RTU now uses 2 stop bits in autobaud
Modbus
RTU now checks for valid slave ID on response
Bug
fixes
RTRIM$
fixed
H
Address
of x0000 on one-based Modbus no longer allowed
Timers
now more reliable
Timers
now remove faster from project
Various
extreme errors in BASIC no longer cause HMI to crash
Trend
chart no longer causes resource leak
Download
Fail problems fixed
Pictures
no longer autoresize when choosing a new file name
Driver setup list now sorted properly for more than 10 drivers
WinBuild
5000 Version 1.11 (10/31/2003)
Whats New
Omron
Hostlink driver added
Indramat
DKC driver added
Bug fixes
Problem
with non-circular trend with data acq larger than the trend fixed
Report
writer for data acq driver fixed.
Install
problem with DAO files fixed
WinBuild
5000 Version 1.1 (10/21/2003)
Whats New
Data
Acquisition driver added
Internal
System driver added
Trend
Charts added
SetTrendRange
object property added
MSECTOTIME$
function added
Bug fixes
Crash in
Find Code dialog fixed
Modbus
string slave reads fixed
Modbus
string master writes fixed
Generic
TCP can now be one of the middle drivers
WinBuild
5000 Version 1.05 (8/26/2003)
Whats New
Many
useful pictures are now available in the Graphics directory
Model 6501
IO Configuration Utility added to Tools menu
Bug fixes
COM
pseudocodes now work properly
Communication
setup made easier to use
Gauge
widget now displays labels for negative arcs properly
Unit will
now go into configuration mode if program is not downloaded
WinBuild
5000 Version 1.04 (8/04/2003)
Whats New
Gauge
widget added
Generic
TCP driver added
Compumotor
EVM capability added to Compumotor driver
Bug fixes
Data entry
boxes now horizontally justify properly
Message
displays for array elements work properly
Popup()
command now works on superbuttons
BASIC code
executes before data entry display
Popup data
display will always display changed text
Name
changes from Eason Technology to ESA Technology
Case
sensitivity no longer requires on object properties
WinBuild
5000 Version 1.03 (7/07/2003)
Bug fixes
Nonvolatile
driver fixed
Subroutines
not being called problem fixed
WinBuild
5000 Version 1.02 (6/30/2003)
Whats New
Emerson
AXIMA driver added
Emerson E
Series driver added
Yaskawa
MEMOBUS driver added
Compumotor
6K Ethernet driver added
Demo
programs
Bug fixes
Bug where
bad driver pseudocode caused crash was fixed
Bug where
Compumotor 6K would not init was fixed
Bug where
PC104 Galil would not init or download program was fixed
WinBuild
5000 Version 1.01 (6/13/2003)
Whats New
Compumotor
6000/6K/GT6K driver added
Automation
Direct/Koyo serial driver added
Bug fixes
Bug